Products
Knowledge
This webpage doesn't work with Internet Explorer. Please use the latest version of Google Chrome, Microsoft Edge, Mozilla Firefox or Safari.
require 3 characters or more.
The information presented in this cross reference is based on TOSHIBA's selection criteria and should be treated as a suggestion only. Please carefully review the latest versions of all relevant information on the TOSHIBA products, including without limitation data sheets and validate all operating parameters of the TOSHIBA products to ensure that the suggested TOSHIBA products are truly compatible with your design and application.
Please note that this cross reference is based on TOSHIBA's estimate of compatibility with other manufacturers' products, based on other manufacturers' published data, at the time the data was collected.
TOSHIBA is not responsible for any incorrect or incomplete information. Information is subject to change at any time without notice.
require 3 characters or more.
When a short-circuit between a load on the VOUT side and GND or other system failure occurs, this function limits the output current of an LDO regulator to protect itself and the system in which it is used. Toshiba’s LDO regulators provide overcurrent protection called foldback. In the event of excessive current higher than the internal threshold, foldback reduces the output current (IOUT) as the output voltage (VOUT) decreases. Even when the output voltage has reached 0 V, the output current continues flowing at the internally set level. The term “foldback” is derived from the shape of the IOUT-vs-VOUT curve that folds back as shown below during protection operation. When a faulty condition causing an overcurrent condition disappears, an LDO regulator automatically recovers from overcurrent protection, returning the output voltage to the normal level.
The following links also provide a description of overcurrent protection:
Application note: Basics of Low-Dropout (LDO) Regulator ICs
FAQ: How does overcurrent protection work in an LDO regulator?
You can perform a parametric search of LDO regulators with an overcurrent protection function:
Parametric search of LDO regulators with an overcurrent protection function