The information presented in this cross reference is based on TOSHIBA's selection criteria and should be treated as a suggestion only. Please carefully review the latest versions of all relevant information on the TOSHIBA products, including without limitation data sheets and validate all operating parameters of the TOSHIBA products to ensure that the suggested TOSHIBA products are truly compatible with your design and application.
Please note that this cross reference is based on TOSHIBA's estimate of compatibility with other manufacturers' products, based on other manufacturers' published data, at the time the data was collected.
TOSHIBA is not responsible for any incorrect or incomplete information. Information is subject to change at any time without notice.
型號需要超過三個文字以上
One of the possible causes of this is the tripping of undervoltage lockout (UVLO*). When the input voltage of an LDO drops to the predefined threshold, UVLO disables the LDO to prevent false operation. The LDO is re-enabled when the input voltage rises above the recovery threshold. ULVO has a hysteresis.
* UVLO: Under Voltage Lock Out