The information presented in this cross reference is based on TOSHIBA's selection criteria and should be treated as a suggestion only. Please carefully review the latest versions of all relevant information on the TOSHIBA products, including without limitation data sheets and validate all operating parameters of the TOSHIBA products to ensure that the suggested TOSHIBA products are truly compatible with your design and application.
Please note that this cross reference is based on TOSHIBA's estimate of compatibility with other manufacturers' products, based on other manufacturers' published data, at the time the data was collected.
TOSHIBA is not responsible for any incorrect or incomplete information. Information is subject to change at any time without notice.

關鍵字搜尋

參數搜尋

線上庫存查詢跟購買

Select Product Categories

Chapter III : Transistors : Performance of MOSFETs: Safe Operating Area(or Area of Safe Operation)

There are two modes of safe operating area (SOA).

(1) Forward Bias SOA (F.B. SOA): Usable area of current and voltage at ON status.
(2) Reverse Bias SOA (R.B. SOA): Usable area of current and voltage at turn-off operation.

Applied pulse width is very narrow because of use under switching operation.

Each mode can be defined as shown in Fig. 3-12(a).

Defining SOA in actual operation
Fig. 3-12(a) Defining SOA in actual operation
Example of MOSFET’s F.B.SOA
Fig. 3-12(b) Example of MOSFET’s F.B.SOA
  • As for the guarantee of avalanche, rated voltage / current operation (short time) at turn-off is generally guaranteed as for the MOSFET, but R. B. SOA has not been announced.
  • F.B.SOA consists of three restriction areas, rated current, rated voltage and thermal resistance areas, and secondary breakdown area.
  • The three restriction areas are limited by ratings of device or calculated from thermal resistance. But secondary breakdown area is obtained by measurement of the actual device.